ECL 760 Transasia Advanced Fully Automated Random Access Coagulation Analyzer
Product Brochure
Brand | Transasia |
Model Name/Number | ECL 760 |
Weight | 53 kg |
Printer | Built-in printer |
Dimension (L x W x H) | 660 x 580 x 510 mm |
Storage Environment | -20 Degree C ~ 55 Degree C, relative humidity < 85% |
Operational Environment | 10 Degree C ~ 30 Degree C, relative humidity < 70% |
Input Power | 400VA |
Mains Input | AC 100V/220V, 50Hz or 60Hz |
Factor Assay | Generation of Standard curve |
Database | 100,000 test results, 10,000 clot curves |
Operating System | Windows XP |
Display | 8" LCD Graphical touch screen display |
Total Number of Samples | 27 numbers, continuous loading |
ECL 760 is an advanced, fully automated random access analyzer for complete hemostasis. This seven channel coagulation analyzer redefines the benefits in its class. This system is ideal for mid-high range coagulation workload, especially for routine PT, aPTT and some rare parameters.
Product Features:
- Interactive touch screen interface/ keyboard
- Clotting Graph provides details of the clotting test
- Cuvette and reagent management software
- Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors and multirules.
- Temperature stability at 37 degree C to perform the tests
- Low Reagent Consumption
- Windows software
- CE mark
Product Applications:
- Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S can be performed using Light scatter principle
- Protein C, Antithrombin III can be done by Chromogenic Principle
- Tests like D Dimer can be performed using Immuno-turbidimetry principle
Sanli VTM Throat/oropharyngeal Viral Transport Medium Kit
Model Name/Number | SANLI VTM |
Kit Contents | Swab, Viral Tranport Medium |
Number of Reactions(Preps) per Kit | 1 |
Number of pieces per pack | 20 |
Brand | SANLI (Horiba) |
Test Method | (SARS-CoV-2) PCR |
Sample Type | Nasal Swab |
Application | COVID-19 Sample |
PRODUCT INFO
DISPOSABLE VIRUS SPECIMEN COLLECTION TUBE
(VIRAL TRANSPORT MEDIA)
1. Product Name: Disposable Virus specimen collection tube (Viral Transport Medium)
2. Intended Use: intended for the collection and transport of clinical specimens including viruses and chlamydiae, mycoplasma or ureaplasma from the collection site to the testing laboratory from the collection site to the testing laboratory
3. Main structure: This product is mainly composed of 2 pcs of swabs (1 throat Swab & 1 Nasal Swab) and 3ml viral transport tube. The main components of transport medium are Hanks' Balanced Salt Solution, Phenol red, Bovine serum albumin, Gentamicin, etc.
4 Instruction for use
Step 1 Tear off the package and take out the swab
Step 2 Get sampling with swab from right body parts
Step 3 Place the swab into virus specimen tube all the way to the bottom of the tube
Step 4 Bend the swab at a 180 degrees angle to break at the appropriate point
Step 5 Tighten the cap, shake it several times and complete the sampling
Remarks: After collection, the specimen should be transported to the laboratory within 72 hours with recommended storage temperature of 2-8°C. If delivery and processing exceed 72
hours, specimens should be transported in dry ice and once in laboratory frozen at -70 °C or colder. The specimens should avoid repeated freezing and thawing.
5. Warnings and Precautions:
1) Single-use device for professional in vitro diagnostic use.
2) Do not use beyond the expiry date.
3) Do not re-sterilize unused swabs.
4) Do not re-pack
5) Do not ingest the medium
6) When collecting and handling specimens, gloves, protective clothing, goggles and other personal protective equipments shall be worn to avoid splashing, leakage and exposure of potential pathogens.
7) All biohazardous specimens and devices shall be disposed of in accordance with the relevant regulations and procedures and discarded in the designated collection containers.
8) This product is only used for storage after sample collection and during in vitro transportation, it is only for one-time use and does not have the culture function (< 72 hours), any damaged package is forbidden to use.
9) After use, the waste shall be disposed according to the regulations of the hospital or the environmental protection department.
10) Don’t use if transport media is turbid, discolored and dried
6. Warning and prevention: it is forbidden to use when package damage, foreign matters, leakage, storage liquid turbidity and expiration date are found.
7. Symbol & Mark Key used for packaging.
8. Storage
The product should be stored at 4 25 to avoid direct exposure to sunlight until the time of use. Do not overheat or freeze prior to use.
9. DISPOSAL
Waste must be disposed of in compliance with local legislation. Take the appropriate precautions for infected material if necessary.
Tips Pipette Blue
Minimum Order Quantity: 20 Packet
Product Brochure
Capacity | 200-1000mcl |
Usage/Application | Chemical Laboratory |
Material | Plastic |
Color | Blue |
Semi Automatic Transasia ECL 105 Single Channel Coagulation Analyzer
Product Brochure
Brand | Transasia |
Power Supply | 100-250V ~47-63Hz, 150VA |
Weight | 0.9 kg |
Dimension | 216 x 205 x 75 mm |
Printer | Built-in Graphic Thermal Printer |
User Interface | USB port, Pen Drive / LIS compatible, software upgradable |
Power Consumption | 150VA or less |
Cuvette and Reagent Management | Cuvette usage and reagent lot and expiry management |
Database | >250 results with coagulation Curve |
QC | QC with L-J graph |
Operating Temperature | 17-32 Degrees Celsius, Max. 80% RH, non-condensing |
Reagents | 6 point Multi-standard Graph, on display on print |
Units of Measurement | Seconds, %, INR, mg/dl, g/dl, ratio, etc |
Reagent Cup Holder | 5 Positions (4 cups and 1 bottle with programmable stirring option) |
Reaction Cuvette Holder | 5 Positions for incubation of single reaction cuvette |
Display | Large graphical touch screen display |
Number of Channel | One |
Test Menu | PT, APTT, FBG, Intrinsic and Extrinsic Factor Assays, LA, PS and D Dimer, programmable |
Principles | Clotting assays, Light Scatter Principle (640nm), Immunogenic Turbidimetric Assays (800nm) |
ECL 105 is a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factors, Lupus and DDimer.
Product Features:
- Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle
- Tests like D Dimer performed using Immuno-turbidimetry principle
- Interactive touch screen interface
- Clotting Graph provides details of the clotting testCuvette and reagent management software
- Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors
- Temperature stability at 37 degree C to perform the tests.
- Low Reagent Consumption
- USB Connectivity
- CE mark
Product Applications:
- ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT
- It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII
- It is used as Standby to bigger systems, in accredited centres
- It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc.
Semi Automatic Transasia ECL 412 4 Channel Coagulation Analyzer
Product Brochure
Brand | Transasia |
Weight | 3 kgs |
Printer | Built-in Graphic Thermal Printer |
User Interface | USB port, Pen Drive / LIS compatible |
Dimension and Weight | 300 x 290 x 90 mm |
Hardware | Micro processor based system |
Power Requirement | 100-250V ~47-63Hz, 150 VA |
QC | QC with L-J graph |
Operating Temperature & Humidity | 17-32 Degrees Celsius, Max. 80% RH, non-condensing |
Calibrator | 6 point calibration on display and print curve data |
Units of Measurement | seconds, %, INR, mg/dl, g/dl, etc |
Display | Large Graphical Touch Screen Color Display |
Reagent Cup Holder | 12 Positions (10 cups and 2 bottles with stirring programmable) |
Reaction Cuvette Holder | 20 Positions for incubation of single reaction cuvette |
Number of Channels | 4 Channels |
Test Menu | PT, APTT, FBG, Intrinsic and Extrinsic Factor Assays, LA, PS, PC, Chromogenic ATIII and D Dimer, pr |
Light Source | LED |
Principles | Clotting assays, Light Scatter Principle (640nm), Chromogenic Assays (405nm), Immunogenic Turbidimet |
ECL 412 is an advanced analyzer for Complete Hemostasis. This four channel coagulation analyzer redefines the benefits in its class. Erba ECL 412, can perform PT, APTT, Fibrinogen, Thrombin Time , All Factors, Lupus , Protein S, Protein C , Antithrombin III and DDimer.
Product Features:
- Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S performed using Light scatter principle.
- Protein C, Antithrombin III done by Chromogenic Principle
- Tests like D Dimer performed using Immuno-turbidimetry principle
- Interactive touch screen interface
- Clotting Graph provides details of the clotting test
- Cuvette and reagent management software
- Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors
- Temperature stability at 37 degree C to perform the tests
- Low Reagent Consumption
- USB Connectivity
- CE mark
Product Applications:
- ECL 412 has uses in various routine IVD labs for doing routine PT and aPTT
- It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII
- It is used as Standby to bigger systems, in accredited centers
- It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc
TrueHb Hemometer
Minimum Order Quantity: 1 Piece
Product Brochure
Operation Mode | Auto Calibration |
Brand | TrueHb |
Power Supply | Rechargeable |
Country of Origin | Made in India |
Usage | For ultra convenient hemoglobin measurement |
Packaging Size | 1 Strip |
Display Type | Digital |
Additional Information:
- Delivery Time: 10 Days
Typhoid IgG/IgM Rapid Test
Minimum Order Quantity: 40 Piece
Usage/Application | Hospital |
Material | Plastic |
Results | Fast Result |
Country of Origin | Made in India |
Individually Packed cassette devices | 30 Nos. |
Plastic Droppers | 30 Nos. |
Sample Diluent (5 ml/bottle) | 1 Nos. |
Package insert | 1 |
Method | Rapid |
Additional Information:
- Delivery Time: 10 Days
CoaguChek XS System
Minimum Order Quantity: 1 Piece
Brand | CoaguChek |
Power Supply | Battery - Four 1.5v AAA alkali-manganese batteries |
Weight | 127 gm (without batteries) |
Height | 4300 m |
Humidity | 85% |
Country of Origin | Made in India |
Material | Plastic |
Size | 138 x 78 x 28 mm |
Memory | 300 test results with time and date |
Backed by the sound production facilities, we have emerged as one of the foremost suppliers of CoaguChek XS system.
Corn Plaster
Color | Skin |
Categories | Long Stretch Compression |
Size | 28 mm X 76 mm |
Length | 28 mm X 76 mm |
Model Name/Number | 94911011MN |
Brand | Hansaplast |
Vandana Absorbent Cotton Wool I.P
Usage/Application | Hospital and Commercial |
Type | Plain Dyed |
Packaging Material | Polyethene and Paper |
Sterility | Sterile |
Color | White |
Brand | Vandana |
Auto Hematology Analyzer BC-6000
Minimum Order Quantity: 1 Piece
Operation Mode | Fully Automatic |
Usage/Application | Hospital |
Brand | Mindray |
Differential Type | 5-Part |
Model Name/Number | BC-6000 |
Features | Fast Result |
- Unique SF Cube technology
- Reveal more abnormal cells
- NRBC result in every CBC
- More accurate RET result
- Improved Optical + Fluorescent PLT???PLT-O???
- Built-in body fluid analysis
- Malaria Screening
- labXpert
- Rerun & Reflex
- Touch screen
- High throughput and capacity
Additional Information:
- Delivery Time: 10 Days
Fully Automated Hematology Analyzer BC- 6800
Minimum Order Quantity: 1 Unit
Operation Mode | Fully Automatic |
Usage/Application | Hospital |
Brand | Mindray |
Differential Type | 5-Part |
Model Name/Number | BC-6800 |
Features | Fast Result |
Additional Information:
- Delivery Time: 10 Days
Stat Fax 3000 Semiauto Biochemistry Analyzer
Minimum Order Quantity: 1 Piece
Brand | Stat Fax |
Usage/Application | Hospital |
Model Name/Number | Stat Fax 3000 |
Country of Origin | Made in India |
Color | Black |
Body Material | Plastic |
Flow Cell Glass Type of System Open
Features:
- Statfax 3000plus USFDA approved instrument Company.
- Long Lasting IAD (Ion Assisted Deposition ) filters for extensive life span, reliability and accuracy
- GaAsP Photodiode ensures accurate and reproducible results due to excellent sensitivity and high linearity
- Dual mode (flow cell and cuvette)
- Live plotting of Kinetic assays with Linear Phase Selection (LPS)
- On board curve editing - for easy performance of multipoint calibration
- Vaccum pump aspiration mode
Fully Automated Hematology Analyzer Bc-5000
Operation Mode | Fully Automatic |
Usage/Application | Hospital |
Brand | Mindray |
Differential Type | 5-Part |
Model Name/Number | BC-5000 |
Method | Flow Cytometry |
Display | Digital |
Features | Fast Result |
Country of Origin | Made in India |
Additional Information:
- Delivery Time: 10 Dyas
Qlabs Poct Handheld Electrometer Model Q-1 Inr Meterr
Operating Temperature Range | 10 Degree to 35 Degree C |
Operating Humidity Range | Up to 90 % RH |
Shelf Life at Room Temperature | 18 months |
Sensitivity to Heparin Insensitive | Up to 3 U/mL blood (unfractionated & LMW) |
Hematocrit Range | 55% |
Result | 2 minutes |
qLabs® platform, enables (Fingerstick blood) rapid testing by patient-side, so that health care professionals and patients themselves can access real-time, lab-quality results within minutes, right at Point of Care or at home. The qLabs® platform is a rapid testing system that is composed of a handheld qLabs® ElectroMeter and disposable strips. Lightweight, portable, compact and easy to use.
Features:
- Single-use and cost effective disposable strip
- Lightweight and compact handheld meter
- High precision with lab quality: 5% CV
- Fingerstick blood: less than 10 µl
- Rapid testing: 1-5 minutes
- On board quality control
- User-friendly operation
- PT results displayed in about 2 minutes
- Heparin neutralization
- Proprietary cross-talk reduction technology to ensure high precision.
CLIA Waiver compliance On board quality controls Dry-reagent strips stored at room temperature for immediate use, no equilibration required High Isolation between channels for high precision Strong correlation to central laboratory results Built in communication port for a printer and
connectivity software LOW ISI as recommended by ACCP, CAP, and WHO
Sample Types and Volume Fingertip.
Bene Sphera Blood Collection Tube K3 Edta 2ml
Minimum Order Quantity: 50 Packet
Usage/Application | Clinical, Hospital, Laboratory |
Brand | BeneSphera |
Material | Plastic |
Anticoagulant | K3 EDTA |
Packaging Type | Box |
Capacity | 2 ml |
Country of Origin | Made in India |
Packaging Size | 100 Pieces |
Additional Information:
- Delivery Time: 10 Days
Krupa Labequi EQUI Vac Clot Activator 4mL
Type Of Medical Tubes | Blood Collection Tube |
Brand | Adrib |
Product Contain | Blood Collection Tube |
Usage/Application | Hospital |
Material | Pet |
Usability | Disposable |
Krupa Eque Tube K3 Edta
Usage/Application | clinical,hospital,laboratory |
Brand | Krupa |
Material | Plastic |
Size | 2 ml |
Mindray Chemiluminescence Analyzer (CL-960i)
Minimum Order Quantity: 1 Unit
Model Name/Number | CL-960i |
Brand | Mindray |
Usage/Application | Laboratory Use |
Operation Mode | Fully Automatic |
Throughput | Up to 180 tests/Hour. |
Color | Black and White |
Country of Origin | Made in India |
Sample Volume | Up to 200u, with increment of 1ul |
Additional Information:
- Delivery Time: 10 Days
Acharya Lab Consumables BCT(K3)
Usage/Application | Laboratory |
Material | PET |
Size | 12.4x75 mm |
Country of Origin | Made in India |
Capacity | 4 ml |
Packaging Type | Box |
Ozocheck Blood Pressure Monitor
Usage/Application | Hospital,clinic,personal |
Accuracy | + - 3% |
Ozone is it One step (Pregnancy) Test Device
Minimum Order Quantity: 5 Packet
Usage/Application | Hospital |
Electronic Needle & Syringe Destroyer
Brand | SAI+Life |
Material | Iron |
Automation Grade | Automatic |
Surface Finish | Powder Coated |
Weight | 699 g |
Input Voltage | 220-240 Volt |
Dimensions | 22 x 18 x 13 cm |
- Turn Switch on
- Insert needle into hole
- Press & Rotate
- Remove S. Tube of needle
- Insert Syringe to cutter
- Take out tray for removeal of waste
- Turn switch off
Afford Isopropyl Alcohol Lr Grade
Purity % | >99% |
Usage/Application | Manufacturing sanitizers |
Grade Standard | Analytical AR Grade |
CAS No | 67-63-0 |
Brand | Afford |
Physical State | Liquid |
Country of Origin | Made in India |
Packaging Size | 4.5 Litre |
Packaging Type | Can |
Isopropyl Alcohol Price List
Packaging Details | Price |
4.5 litre bottle | Rs 800 |
25 litre drum | Rs 20000 |
Get Best price of >99% pure 25 litre drum of Isopropyl Alcohol CAS No. 63-67-0, C3H8O. For Certificate of Analysis (COA) & MSDS, kindly contact us.
Uses:
- Used in paint industry
- Used for rubber manufacturing industry
- Pharmaceutical applications
- lacquer formulations, dye solutions, antifreezes, soaps, window cleaners
- Used for making sanitizers
- Major component in Industrial & household cleaners
Isopropyl alcohol (IUPAC name propan-2-ol; also called isopropyl, isopropanol, or 2-propanol) is a colorless, flammable chemical compound (chemical formula CH3CHOHCH3) with a strong odor. As an isopropyl group linked to a hydroxyl group, it is the simplest example of a secondary alcohol, where the alcohol carbon atom is attached to two other carbon atoms. It is a structural isomer of 1-propanol and ethyl methyl ether.
Isopropyl alcohol, particularly in solutions between 60% and 90% alcohol with 10 – 40% purified water, is rapidly antimicrobial against bacteria, fungi, and viruses. Once alcohol concentrations drop below 50%, usefulness for disinfection drops sharply. Notably, higher concentrations of alcohol don’t generate more desirable bactericidal, virucidal, or fungicidal properties. Alcohol-based versions typically contain some combination of isopropyl alcohol, ethanol (ethyl alcohol), or n-propanol, with versions containing 60% to 95% alcohol the most effective. Care should be taken as they are flammable. Alcohol-based hand sanitizer works against a wide variety of microorganisms but not spores. Compounds such as glycerol may be added to prevent drying of the skin. Some versions contain fragrances; however, these are discouraged due to the risk of allergic reactions. Non-alcohol based versions typically contain benzalkonium chloride or triclosan; but are less effective than alcohol-based ones.
Isopropyl alcohol is effective against viruses such as FCV at 40% – 60% concentrations.
Methods of Manufacturing:
- Indirect hydration process is based on a two-step reaction of propylene and sulfuric acid; in the first step, mixed sulfate esters, primarily isopropyl hydrogen sulfate, but also diisopropyl sulfate, form; these are then hydrolyzed, forming isopropanol and sulfuric acid.
Health Hazards:
- Vapors cause mild irritation of eyes and upper respiratory tract; high concentrations may be anesthetic. Liquid irritates eyes and may cause injury; harmless to skin; if ingested causes drunkenness and vomiting.
Fire Hazards:
- Highly flammable. Vapour/air mixtures are explosive. Risk of explosion on contact with strong oxidants.
First Aid:
- EYES: Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center.
Additional Information:
- Delivery Time: 7-10 Days
Syringe Destroyers
Minimum Order Quantity: 1 Piece
Brand | Tubler |
Usage/Application | Hospital |
Material | Plastic |
Color | Black |
Packaging Type | Box |
Country of Origin | Made in India |
Hospitals and Medical Nursing Homes are constantly using and disposing a large quantity of needles every day. These sharp needles can be very dangerous if not destroyed in a proper way. Tubler brand different kinds of needle destroyers to facilitate the hospital to dispose off its needles in the required manner. These instruments manufactured by Raj Biosis Pvt Ltd are very clinically designed to dispose off the needles as per the need to keep the environment safe and guard the hospital waste from medical hazards. You can view our different products in this category and order according to the need of your hospital for destroying the used needles and syringes.
Infrared Thermometer
Brand | Besiter |
Usage | Non-Contact/Medical |
Measuring Range | 32 - 42 .9 Degree C |
Type | Gun |
Micropipette 100-1000ul
Minimum Order Quantity: 1 Piece
Model | Qipette |
Model Number Bioshine
Type Micro
Capacity 1000 microliter
Material Plastic
Usage Type Reusable
Warranty 1 Year Replacement Warranty
With Meity Calibration Report
Reagent Strip SD
Minimum Order Quantity: 5 Bottle
Product Brochure
Number of Strips | 100 Strips |
Model Name/Number | SD urocolor |
Usage/Application | Laboratory Use |
Brand | SD Uro color |
Material | Plastic |
Shelf Life | 24 Months |
Features | Simple Easy to use Fast results Reliable |
Country of Origin | Made in India |
We are a highly renowned company engaged in the provision of premium quality Urine Reagent Protein Strips. These strips are a quick and reliable means of getting urine analysis or urine test done. The simplicity of this test ensures that it can be done at home sans any help or assistance. These reagent strips are available to clients at leading market prices in multiple sizes, shapes and thickness.
BloodDiseases#BloodTests#BloodCount#MDS (Myelodysplastic Syndromes)#Hematopoiesis#MPN (Myeloproliferative Neoplasms)#BMT (Bone Marrow Transplant)#Thalassemia#Hemato#Hemostasis#BloodClots#Hemoglobin#FlowCytometry#HematologyLab#TransfusionMedicine#HematologyNursing#Hemoglobinopathies#HematologyCases#BloodDonation#IronDeficiency#BloodSmear#HematologyTechnician#HemoglobinElectrophoresis#HemolyticAnemia#MyeloproliferativeDisorders#HemophiliaAwareness#BloodCancerAwareness#HematologyNews#HematologyGuidelineslogyEducation
Measuring Cylinder 100ml
Minimum Order Quantity: 20 Piece
Product Brochure
Shape | Cylindrical |
Capacity | 100ml |
Brand | NET |
Material | Plastic |
Automation Grade | Manual |
Usage/Application | labs and hospital |
Color | white or transparent |
1. Professional lab Plastic measuring cylinder.
2. Clear and accurate metric scale.
3. A good tool for Chemistry Labs & PH value.
4. Suitable for both family use and professional experiment.
Specifications:
1. Color: clear
2. Material: Plastic
3. Capacity: 100ml
Package includes:
Plastic Measuring Cylinder(s)
#BloodClots#Hemoglobin#FlowCytometry#HematologyLab#TransfusionMedicine#HematologyNursing#Hemoglobinopathies#HematologyCases#BloodDonation#IronDeficiency#BloodSmear#HematologyTechnician#HemoglobinElectrophoresis#HemolyticAnemia#MyeloproliferativeDisorders#HemophiliaAwareness#BloodCancerAwareness#HematologyNews#HematologyGuidelineslogyEducation
Semi Auto Biochemistry Analyzer
Product Brochure
Brand | Qlyser |
Model Name/Number | Chem77 |
Assays | Clinical Chemistry |
Type Of System | Open |
Application | Research Use, Veterinary Use, Clinical Use, Research Use,In-Vitro Diagnostic Use,Veterinary Use,Clinical Use,Hospital Use, In-Vitro Diagnostic Use, Hospital Use |
Automation Grade | Semi-Automatic |
Programmable Test Memory | 100 Tests,200 Tests,300 Tests, 100 Tests |
Features | Bench-Top, Bench-Top,Portable |
Brand Preference | Abott,Mindray,Wiener Lab.,Shenzhen |
Features:
7 inch color-LCD Touch screen
Real time curve showing
7 wavelength 80 test items pre-programmed
Memory for 10,000 sample results
Light source hibernate function making lamp long life time
10 Incubators (optional), 37 ± 0.3
RS232 interface, PC connecting
Flow-Cell & Cuvette mode available
Specifications:
Test mode: Kinetic, End point, Twopoint, Absorbance
Wavelength: 7 standard filters, 340, 405, 492, 510, 546, 578, 630nm, 1 free position
Wavelength precision: ±2nm, width≤ 10nm
Absorbance range: 0~4.500 Abs
Absorbance precision: outside 0.0001 Abs, inside 0.00001 Abs
Carryover: ???1%
Repeatablity CV: ???1%
Incubator: 37 30 25 and others, Precision: ±0.1 Optinal
Sample volume: 0~3000ul( 500ul recommend)
Data Storage: 10000
Quality control curve: X SD CV% L-J quality control curve for each test item
Flow cell: 32 ul quartz glass, 10mm
Lamp: Phllips 6V 10W Halogen Lamp with longer life time
Screen: 7 inch color LCD
CPU:ARM series high speed micro CPU
Printer:Internal thermal sensitive printer
Interface: RS-232
Work Environment: Temperature 0 40
Humidity: 80%
Power supply: 100~240VAC, 50~60Hz, 100VA
Dimension: L340mm* W270mm*H160mm
Net Weight: 5KG Gross Weight: 10.5KG
Syphilis / Tp Test Modified Tpha Device
Product Brochure
Brand | Syphilis |
Usage/Application | Hospital |
Form | Card |
Method | Lateral Flow Immuno Assay |
Country of Origin | Made in India |
Packaging Type | Box |
13100mm Blood Collection Tube
Minimum Order Quantity: 5 Box
Product Brochure
Usage/Application | Laboratory |
Anticoagulant | yes |
Is It Sterilized | Sterilized |
Country of Origin | Made in India |
- Sample tubes for AA, ICP, ICP-MS, ICP-OES, TOC, UV-VIS, HPLC, FIA, GPC, fraction collection and liquid handling applications.
- Tubes are standard sizes and fit Cetac, Elemental Scientific and AIM Lab 60 and 90 position racks used by many instrument manufacturers including Agilent, Lachat, Leeman Labs, PerkinElmer, Spectro and Thermo. Our tubes also fit systems by Dionex, Gilson, and Varian.
Additional Information:
- Production Capacity: 500000 PCS/Day
- Delivery Time: 2-7day
- Packaging Details: Sample tubes for AA, ICP, ICP-MS, ICP-OES, TOC, UV-VIS, HPLC, FIA, GPC, fraction collection and liquid handling applications.
Awareness Technology Stat Fax 3000 Semiauto Biochemistry
Minimum Order Quantity: 1 Piece
Analysis Method Fixed-Time, Kinetic, End-point
Assays Clinical Chemistry, Special Proteins
Test method Fixed-time, Kinetic, End-point
Reaction Cuvette Disposable Cuvette, Flow Cell, Reusable Cuvette
Flow Cell Glass
Type of System Open
Product description
Features
Statfax 3000plus USFDA approved instrument Company.
Long Lasting IAD (Ion Assisted Deposition ) filters for extensive life span, reliability and accuracy
GaAsP Photodiode ensures accurate and reproducible results due to excellent sensitivity and high linearity
Dual mode (flow cell and cuvette)
Live plotting of Kinetic assays with Linear Phase Selection (LPS)
On board curve editing - for easy performance of multipoint calibration
Vaccum pump aspiration mode.
TransfusionMedicine#HematologyNursing#Hemoglobinopathies#HematologyCases#BloodDonation#IronDeficiency#BloodSmear#HematologyTechnician#HemoglobinElectrophoresis#HemolyticAnemia#MyeloproliferativeDisorders#HemophiliaAwareness#BloodCancerAwareness#HematologyNews#HematologyGuidelineslogyEducation
#Hematology#BloodDisorders#BloodCancer#Anemia#Leukemia#Lymphoma#Thrombosis#BloodTransfusion#CoagulationDisorders#BoneMarrow#Myeloma#SickleCell#Hemophilia#PlateletDisorders#Hematopathology