Glucose:This test is based on a double sequential enzyme reaction.One enzyme, glucose oxidase, catalyzes the formation of gluconic acid & hydrogen peroxide from the oxidation of glucose. A second enzyme, peroxidase, catalyzes the reaction of hydrogen peroxide with a potassium iodide chromogen to oxidize the chromogen to colors ranging from green to brown.
Bilirubin:This test is based on the coupling of bilirubin with diazotized dichloraniline in a strongly acid medium.The color ranges through various shades of tan.
Ketone :This test is based on the development of colors ranging from buffpink, for a negative reading, to purple when acetoacetic acid reacts with nitroprusside.
Specific Gravity :This test is based on the apparent pKa change of certain pretreated polyelectrolytes in relation to ionic concentration. In the presence of an indicator, colors range from deep bluegreen in urine of low ionic concentration through green & yellow green in urines of increasing ionic concentrations.
Blood:This test is based on the peroxidaseiike activity of hemoglobin, which catalyzes the reaction of diisopropylbenzene dihydroperoxide & 3,3',5,5'tetra methylbenzidine. The resulting color ranges from orange through green; very high levels of blood may cause the color development to continue to blue.pHThe test is based on the double indicator principle that gives a broad range of colors covering the entire urinary pH range. Colors range from orange through yellow & green to blue.
Protein :This test is based on the proteinerrorofindicators principle. At a constant pH, the development of any green color is due to the presence of protein. Colors range from yellow for "Negative" through yellowgreen & green to greenblue for "Positive" reactions.
Urobilinogen: This test is based on a modified Ehrlich reaction, in which pdiethylaminobenzaldehyde in conjunction with a color enhancer reacts with urobilinogen in a strongly acid medium to produce a pinkred color.
Nitrite: This test depends upon the conversion of nitrate (derived from the diet) to nitrite by the action of Gram negative bacteria in the urine. At the acid pH of the reagent area, nitrite in the urine reacts with parsanilic acid to form a diazonium compound in turn couples with 1,2,3,4tetrahydrobenzo(h)quinolin3ol to produce a pink color.
Semi Automatic Transasia Laura SMART Compact Urine Strip Reader
Product Brochure
Model Name/Number | Laura Smart |
Brand | Transasia |
Automation | Semi Automatic |
Dimensions | 230 x 127 x 110 mm |
Temperature | 20 - 25 Degree C |
Weight | 0.8kg without adapter, battery and paper roll |
Country of Origin | Made in India |
Wavelengths | 470, 540, 650 nm |
Incubation Period | 55 s |
Touchscreen | Color TFT LCD display (320 x 240 pixels) |
Relative Humidity | 80 % |
Power Consumption | 20 W max. / 1 W standby |
Portable Mode | 6 x 1.5 V (type AA) batteries |
Power Source | Normal mode: 9V DC switch adapter, AC 90 - 230 V / 50 - 60 Hz |
Laura Smart is a simple, quick and compact solution for routine clinical laboratories, ambulances and para clinics. It helps in automated timing, measurement and evaluation of urine test strips.
Product Features:
- Two measuring modes (Standard: 60 samples/h & Smart Timing:240 samples/h)
- Portable mode using batteries
- Calculation of Microalbumin & Creatinine ratio
- Easy operation via touchscreen
Product Applications:
- Automated reading of Urine test strips avoiding subjective errors in visual reading
Urit-180 Urine Analyzer
Minimum Order Quantity: 1 Unit
Product Brochure
Dimensions | 320mm x 300mm x 120mm |
Throughput | Standard mode: 60 samples/hour Fast mode:120 samples/hour |
Weight | 3.5 Kg |
Power Supply | 100-240VAC, 50/60Hz |
Environmental Temperature | 15-30 Degree C, RH:20%-80% |
Strip | URIT 10G/11G urine reagent strips(14G optional) |
Memory Capacity | 4000 results |
Display Type | LCD Screen |
Reaction Time | 60 seconds |
Measuring Wavelength | 3 LED Wavelength ( 550, 620, 720nm) |
URIT-180 Urine Analyzer A urine analyser is a device used in the clinical setting to perform automatic urine testing.
Additional Information:
- Production Capacity: 10
- Delivery Time: 15
Accurex URIT 12 Meter
Product Brochure
Brand | Accurex |
Dimensions | 102mmx50mmxa19m |
Power | DC 6V(Two CR2032 Batteries) |
Memory | 250 test results |
Measuring Range | Up to 24.0g/dl (g/L Optional) |
Speed | 10 Second |
Strip | H12 Hemoglobin Test Strip |
- Parameter- Hemoglobin, HCT (Hematocrit)
- Principle - Optical reflectance
- Measuring range - 4.0g/dl ~ 24.0g/dl (g/L optional)
- Automatization - Self-checking, auto - judging and displaying malfunction
Sd Uro Color 2p
Minimum Order Quantity: 10 Piece
Brand | SD URO |
Country of Origin | Made in India |
Packaging Type | Box |
Shelf Life | 24 months |
Strength | 60mg/dL |
Sensitivity Level | 25 mIU/mL |
Product Description:
- SD Urocolor series
- Clear positive and negative results.
- Good resistance to humidity.
- Checking the interference in Glucose,Blood,Bilirubin and Nitrite by vitamin C ingested.
- No color change after testing is completed.
- No color spread between pH and specific Gravity.
- No interference in protein by alkaline urine.
- Fast result visually or instrumentally.
Siemens Uristix 2p
Minimum Order Quantity: 10 Piece
Brand | Siemens |
Country of Origin | Made in India |
Packaging Type | Box |
Packaging Size | 100 Strips |
Number of Parameters | 2 |
Read Type | Visual Read and Automatic, Visual Read |
Features:
- Chek-Stix urinalysis control strips
- All positive
Agd Ck-Mb (Immuno Inhibition) 10 Ml
Minimum Order Quantity: 50 Pack
Brand | AGD |
Size | 10 ml |
Packaging Type | Box |
Usage/Application | Hospital |
Form | Liquid |
Shelf Life | 18 Months |
Result Time | 3 min |
Country of Origin | Made in India |
Storage Temperature | 2 to 8 Degree C |
- Wide range of Clinical Chemistry Kits
- Liquid stable Reagents
- Accurate & Precise results and high Linearity
- Pack size as per requirement
- Kits provided with Standards
- Special Tests Kits with Calibrators
- Mono Vials for Special Tests
Additional Information:
- Item Code: AGD-MB10
- Delivery Time: 10 Days
Makesure Urine Reagent Strips
Brand | Makesure |
Pack Size | 100 Strips |
Product Leaflet | 1 Nos |
Pouch type | Desiccant Pouch |
Specimens | Urine |
Rajbiosis Mission U120 Smart Urine Analyzer
Minimum Order Quantity: 1 Piece
Product Brochure
Instrument Name | Biochemistry Analyzer |
Usage/Application | Hospital |
Brand | mission |
Automation | Fully Automatic |
User Input | Keyboard |
Display | Digital |
Storage | Last 2,000 results |
Country of Origin | Made in India |
Fast and Accurate
- Up to 120 tests/hour in Continuous Test Option
- Test categories include Routine, STAT and QC
- Automatic calibration for accurate results and easy operation
Convenient Features
- Can read strips with up to 11 parameters, including Microalbumin/Creatine/Ascorbic Acid
- Record Operator/Patient ID by Manual Entry and Barcode Reader
- Capable of data transfer to an external computer or LIS
Reliable
- Automatically stores last 2,000 results
- Can print up to 3 copies per test for convenient reviewing and easy record keeping
- Option to print results on sticker paper for quick and simple record management
#BloodDisorders:#BloodCancer:
#Thrombosis:
#Transfusion
#BoneMarrow:
#Hemoglobinopathies:
#Coagulation:
#FlowCytometry:
#Hematopathology
rajbiosis Urine Analyzer
Usage/Application | Laboratory |
Brand | Erba |
Display | Digital |
Capacity | 600 strips per hour |
Country of Origin | Made in India |
Evaluation Time | 60 s |
Wavelengths | 470, 525 and 625 nm |
Screen Type | Color LCD display (320 x 240 dot-matrix) |
Memory Capacity | Last 2000 measurements |
Laura M is a quick and simple solution for the analysis of urine, which is designed for use in clinical laboratories. User only needs to dip the test strip into the urine sample and place it in the insert area. The next steps – movement, timing, measurement and evaluation – are done automatically by the urine analyzer.
- Semi-quantitative reflectance photometer
- high throughput and memory capacity
- Measuring using LEDs and colour detector
- Built-in thermal printer
- External communication to PC/LIS via RS232
- Possibility to connect an external keyboard or a bar code reader (BCR) via PS2
- Easy operation with sleek and ergonomic design
- Sophisticated monitoring of strip position
- Waste container for collection of used test strip